Thevenin's theorem replaces a network with a voltage source and a series resistor. Norton's theorem does the same job the other way round: any linear two-terminal network can be replaced by a single current source IN in parallel with a single resistor RN — and the load connected to those two terminals behaves exactly the same. Norton is the dual of Thevenin, and converting between the two takes one line of arithmetic. This post shows how to find IN and RN and works a complete numerical example on the same network used in the Thevenin post, so you can check the two methods against each other.
Figure 1: Norton equivalent of the 24 V network (a), and the load current against load resistance (b). The current is highest — the full 0.8 A — when the load is a short circuit, and it falls as the load resistance grows. (Schematic, not to scale.)
Finding IN — the short-circuit current
Short the two terminals A–B together and find the current that flows through the short. That current is IN. Equivalently, if you already know the Thevenin values, IN = Vth / Rth.
Finding RN — the same resistance as Thevenin
RN is exactly the same resistance as Rth: turn off all independent sources — a voltage source becomes a short circuit, a current source an open circuit — then find the resistance looking into the two terminals. So RN = Rth, and the two equivalents are linked by Vth = IN × RN.
Once you have IN and RN, the load current comes from current division: IL = IN × RN / (RN + RL), the load voltage is VL = IL × RL, and the load power is PL = VL × IL.
Worked example — 24 V, 30 Ω, 60 Ω, load 40 Ω
The same network as the Thevenin post: a 24 V source feeds R1 = 30 Ω in series with R2 = 60 Ω across terminals A–B, and a load RL = 40 Ω is connected across A–B. From the Thevenin analysis we already know Vth = 16 V and Rth = 20 Ω.
Step 1 — Norton current: IN = Vth / Rth = 16 / 20 = 0.8 A. Check it directly: shorting A–B puts a wire across R2, so all the source current flows through the short: 24 / R1 = 24 / 30 = 0.8 A ✓.
Step 2 — Norton resistance: RN = Rth = 20 Ω (same deactivation, same parallel combination: 30 || 60 = 20 Ω).
Step 3 — load current and voltage: by current division, IL = IN × RN / (RN + RL) = 0.8 × 20 / (20 + 40) = 0.8 × 20 / 60 = 0.267 A (267 mA). VL = IL × RL = 0.267 × 40 = 10.67 V.
Step 4 — load power: PL = VL × IL = 10.67 × 0.267 = 2.85 W.
Step 5 — check against the Thevenin result: the Thevenin post gave exactly the same answers for this network — IL = 267 mA, VL = 10.67 V, PL = 2.85 W ✓. As a second check, Kirchhoff's current law at the top node: the current through RN is IN × RL / (RN + RL) = 0.8 × 40 / 60 = 0.533 A, and 0.533 + 0.267 = 0.8 A = IN ✓ — the source current splits exactly between the two parallel branches.
Step 6 — maximum power: as with Thevenin, the load gets the most power when RL = RN = 20 Ω. Then IL = 0.8 × 20 / 40 = 0.4 A, and Pmax = IL² × RL = 0.4² × 20 = 3.2 W — the same maximum the Thevenin post found ✓. At this point the 0.8 A splits equally: 0.4 A through RN and 0.4 A through the load, so half the power is wasted in RN — the same 50% efficiency limit.
Key points to remember
- Any linear network reduces to IN in parallel with RN at two terminals — the dual of the Thevenin equivalent.
- IN is the short-circuit current at the terminals; RN = Rth, found with sources turned off (voltage sources shorted, current sources opened).
- Conversion is one line: Vth = IN × RN and IN = Vth / Rth.
- Worked example: 24 V, 30 Ω, 60 Ω → IN = 0.8 A, RN = 20 Ω; a 40 Ω load draws 267 mA at 10.67 V, taking 2.85 W — identical to the Thevenin result.
- Use whichever equivalent is easier: Norton when the load is in parallel and you want current division, Thevenin when the load is in series and you want a voltage divider.