Ohm's Law and Resistors in Series and Parallel: Worked Example

Author: Abloom Spark Date: November 08, 2026

Ohm's law — V = I × R — is the first equation of electrical engineering, and the series and parallel rules for resistors are the second. Together they answer the most common bench question: how much current will this circuit draw, and how much power will each resistor dissipate? This post states the rules, shows them on a V–I graph, and works one pair of resistors through both connections so the difference is visible in numbers.


Figure 1: The same two resistors in series and in parallel (a), and the V–I graph for each resistance (b). The slope of each line is 1 / R. (Schematic, not to scale.)

Ohm's law

For a resistor, current is proportional to the voltage across it: I = V / R. On a V–I graph this is a straight line through the origin with slope 1 / R — a small resistor gives a steep line (much current), a large resistor gives a shallow line. Power in the resistor is P = V × I = I² × R = V² / R.

Resistors in series

In series, the same current flows through every resistor, and the voltages add. The equivalent resistance is simply the sum: R = R1 + R2 + …. The largest resistor takes the largest share of the voltage (V1 = I × R1) and the largest share of the power. Series is how you divide a voltage down — and why a string of Christmas lights goes dark when one bulb fails.

Resistors in parallel

In parallel, every resistor sees the same voltage, and the currents add. The equivalent resistance is found from 1 / R = 1 / R1 + 1 / R2 + …, or for two resistors, R = (R1 × R2) / (R1 + R2). The equivalent is always smaller than the smallest resistor in the group. The smallest resistor takes the largest share of the current and the power. Parallel is how household loads are wired — each one gets the full supply voltage.

Worked example — 100 Ω and 200 Ω on a 12 V supply

Two resistors, R1 = 100 Ω and R2 = 200 Ω, are connected to a 12 V supply — first in series, then in parallel.

Series: R = 100 + 200 = 300 Ω. Current I = 12 / 300 = 40 mA through both resistors. Voltage across R1: V1 = 0.04 × 100 = 4 V; across R2: V2 = 0.04 × 200 = 8 V. Check: 4 + 8 = 12 V ✓. Power: P1 = 4 × 0.04 = 0.16 W, P2 = 8 × 0.04 = 0.32 W, total P = 12 × 0.04 = 0.48 W.

Parallel: 1 / R = 1 / 100 + 1 / 200 = 3 / 200, so R = 66.7 Ω. Each resistor sees the full 12 V: I1 = 12 / 100 = 120 mA, I2 = 12 / 200 = 60 mA. Total current I = 120 + 60 = 180 mA. Check: 12 / 66.7 = 0.18 A ✓. Power: P1 = 12 × 0.12 = 1.44 W, P2 = 12 × 0.06 = 0.72 W, total P = 12 × 0.18 = 2.16 W.

Compare the two: the parallel connection draws 4.5 times the current and dissipates 4.5 times the power of the series connection (180 mA vs 40 mA, 2.16 W vs 0.48 W) — because the equivalent resistance is 66.7 Ω instead of 300 Ω. The same two resistors, wired differently, behave like completely different loads. That is also why a short circuit — near-zero resistance in parallel with a load — draws a huge current.

Key points to remember

  • Ohm's law: I = V / R; power P = V × I = I²R = V² / R. On a V–I graph the slope is 1 / R.
  • Series: R = R1 + R2, same current everywhere, voltages add; the largest resistor takes the most voltage and power.
  • Parallel: 1 / R = 1 / R1 + 1 / R2, same voltage everywhere, currents add; the equivalent is smaller than the smallest resistor.
  • Worked example (100 Ω + 200 Ω, 12 V): series → 300 Ω, 40 mA, 0.48 W; parallel → 66.7 Ω, 180 mA, 2.16 W.
  • Always check a series result by adding the resistor voltages (must equal the supply) and a parallel result by adding the branch currents (must equal the total).